nitrogen and hydrogen 1.5; 3.5; 50; 10; 20 m

3

/s. The suction pressure for

nitrogen is

p

= 1

10

6

Pa, for hydrogen it is

p

= 1

10

5

Pa, and the

forevacuum pressure is

p

f

= 0

.

1

Pa. The calculation results are given in

the table.

The following characteristics were selected as the controlled parameters:

the blades angle

α

, the channels relative width

a/b

, the channels relative

height

λ

. Flow channel optimization calculation was performed for

optimality criteria: the volume

V

fch and flow channel mass

M

.

The following design arrangements were analyzed (see Table): the

conventional flow channel with an axial flow (1), the flow channel with

Comparing optimal parameters for different design variants of VMP flow channels

S

H

, m

3

/s

Gas

Design

N

0

c

/N

a(m)

V

fch

, m

10

3

M

, kg

1

15/–

6.9

8.9

N

2

2

9/13

4.4

4.8

1.5

3

9/13

5.6

5.3

1

46/–

23

30.8

H

2

2

35/19

18

22.4

3

27/26

17

16.7

1

14/–

15

19.3

N

2

2

9/10

10

11.4

3.5

3

9/11

15.3

13.7

1

45/–

53

70.4

H

2

2

33/18

39.6

49.1

3

27/25

47.3

40.8

1

13/–

39.7

54.4

N

2

2

7/13

22

26.0

5

3

8/11

32.5

34.5

1

44/–

148

206.0

H

2

2

34/20

110

142.0

3

25/28

109

105.8

1

11/–

110

157.1

N

2

2

7/8

73

90.9

3

7/10

85

89.6

10

1

36/–

380

529.9

H

2

2

26/18

270

359.0

3

21/25

255

267.0

1

11/–

230

314.4

N

2

2

7/7

145

181.0

3

7/10

181

195.7

20

1

36/–

755

1066.4

H

2

2

23/24

487

623.0

3

21/24

500

557.0

8

ISSN 0236-3941. HERALD of the BMSTU. Series Mechanical Engineering. 2014. No. 5