Study of Heating Main Units of Axial Rotor-and Piston Pump
| Authors: Zloto T. | Published: 26.01.2014 |
| Published in issue: #4(53)/2003 | |
| Category: Power-generating and Transport Machine Building | |
| Keywords: | |
A technique and results of measuring temperature of friction pairs of axial rotor-and-piston pumps are given depending on viscosity, oil pressure at the pump inlet, on the angular rate of the rotor.
