Research the Wind Effect on the Fans Performance of Air-Cooled Condenser for Geothermal Power Station

Authors: Zhinov A.A. , Shevelev D.V. Published: 09.02.2015
Published in issue: #1(100)/2015  

DOI: 10.18698/0236-3941-2015-1-108-118

 
Category: Power Engineering | Chapter: Machines and Devices, Processes of Refrigeration and Cryogenic Engineering, Air Conditioning  
Keywords: air-cooled condenser (ACC), fan, numerical investigation, wind

The results of numerical studies of the wind effect on the fans performance of the air-cooled condenser (ACC) for geothermal power plant using CFD (Computational Fluid Dynamics) are presented in the article. We consider the modular design for the ACC with a lower positioning of the fans. 3D model of the ACC with surrounding buildings, units and landscape elements is used. Heat transfer surfaces are replaced by anisotropic filter with specified characteristic of total pressure losses, while the fans are presented by filters with head-flow characteristic of the serial fans. Calculations were carried out for the wind from 4 to 30 m/s with four orthogonal directions and the prevailing direction in accordance with the wind rose. Calculations shows the presence of a cluster effect in the considered design ACC, a significant effect of wind direction and speed on performance of module ACC fans.

References

[1] Mil’man O.O., Fedorov V.A. Vozdushno-kondensatsionnye ustanovki [Air-cooled condenser]. Moscow, MEI Publ., 2002. 207 p.

[2] Loytsyanskiy L.G. Mekhanika zhidkosti i gaza [Fluid Mechanics]. Moscow, Drofa Publ., 2003. 840 p.

[3] Zhinov A.A., Shevelev D.V. Simulation of air pressure losses in the finned tube bundle of an air condenser. Jelektr. Nauchno-Tehn. Izd. "Nauka i obrazovanie" MGTU im. N.E. Bauman MSTU [El. Sc.-Tech. Publ. "Science and Education" of Bauman MSTU], 2013, no. 03 (in Russ.). Available at: http://technomag.edu.ru (accessed 01.10.2014). DOI: 10.7463/0313.0544307

[4] Patankar S.V. Numerical heat transfer and fluid flow. Hemisphere Publishing Corporation, 1980. 197 p. (Russ. Ed.: Patankar S.V. Chislennye metody resheniya zadach teploobmena i dinamiki zhidkosti. Moscow, Energoatomizdat Publ., 1984. 152 p.).

[5] Toit C.G. de, Kroger D.G. Modelling of the recirculation in mechanical-draught heat exchangers. R&D Journal, 1993, vol. 9, no. 1.

[6] Backer L. de. PAC® systems & wind mitigation. Proc. of ACC Users Group, GEA Power Cooling, Inc. Thermal Engineering Division, NV Energy Las Vegas, Nevada, November 12-13, 2009. 21 p.

[7] Liu P.Q., Duan H.S., Zhao W.L. Numerical investigation of hot air recirculation of air-cooled condensers at a large power plant. Appl. Therm. Eng., 2009, vol. 29, pp. 1927-1934. DOI: 10.1016/j.applthermaleng.2008.09.011

[8] Lijun Yang, Xiaoze Du, Hui Zhang, Yongping Yang. Numerical investigation on the cluster effect of an array of axial flow fans for air-cooled condensers in a power plant. Chin. Sci. Bull., 2011, vol. 56, no. 21, pp. 2272-2280. DOI: 10.1007/s11434-011-4524-x

[9] Borghei L., Khoshkhoo R. Wind effects on air-cooled condenser performance. Proc. of 8th IASME /WSEAS Int. Conf. on Fluid mechanics & Aerodynamics (FMA ’10), 8th IASME /WSEAS Int. Conf. on Heat Transfer, Thermal Engineering and Environment (HTE ’10) "New aspects offluid mechanics, heat transfer and environment". Taipei, Taiwan, August 20-22, 2010.

[10] Mortensen K. Improved performance of an air cooled condenser (ACC) using SPX Wind Guide Technology at coal-based thermoelectric power plants. Final report of SPX Cooling Technologies, Inc. (Reporting Period: 9/1/08-12/31/10). Overland Park, Kansas, 2010 (unpublished).

[11] Maulbetsch J.S., DiFilippo M.N. Numerical investigation of air-cooled steam condenser performance under windy conditions. Proc. of California Energy Commission, Public Interest Energy Research Program. Institute for Thermodynamics and Mechanics University of Stellenbosch, 2011, CEC-500-2013065, pp. 1-94.

[12] Gao Xiufeng, Zhang Chengwei, Wei Jinjia, Yu Bo. Numerical simulation of heat transfer performance of an air-cooled steam condenser in a thermal power plant. Heat and Mass Transfer, 2009, vol. 45, pp. 1423-1433. DOI: 10.1007/s00231-009-0521-x

[13] Kent D. Zammit. Effect of Wind on ACCs. Proc. of ACC Users Group, GEA Power Cooling, Inc. Thermal Engineering Division, NV Energy Las Vegas, Nevada, November 6, 2009.

[14] Duvenhage K., Kroger D.G. The influence of wind on the performance of forced draught air-cooled heat exchangers. J. Wind Eng. Ind. Aero., 1996, vol. 62, pp. 259277. DOI: 10.1016/S0167-6105(96)00082-7

[15] Wang Q.W., Zhang D.J., Zeng M. CFD simulation on a thermal power plant with air-cooled heat exchanger system in north China. Eng. Comp., 2008, vol. 25, pp. 342-365.