Measurement of nitrogen flow parameters in the vapor-lift mode

Authors: Grechko A.G., Glavatskikh S.B., Zherdev A.A., Emelyanov M.G., Shadrina V.Yu. Published: 08.10.2015
Published in issue: #2(19)/1995  

DOI:

 
Category: Cryogenic Engineering  
Keywords:

The results of experimental investigation of the vapor-lift phenomenon in liquid nitrogen are presented as dependencies of true vapor content and vapor velocity on supplied heat load for pipelines of 10, 20 and 30 mm diameter. It had been found that the vapor velocity ceases to increase at the certain heat load values depending on pipeline diameter.